1. Attachments are working again! Check out this thread for more details and to report any other bugs.

120 vac Level 1 Charger

Discussion in 'Gen 1 Prius Plug-in 2012-2015' started by ukr2, Feb 23, 2012.

  1. ukr2

    ukr2 Senior Member

    Joined:
    Feb 5, 2007
    1,009
    275
    31
    Location:
    Victor, NY
    Vehicle:
    2021 Prius Prime
    Model:
    XLE
    I'm planning to charge my PIP at home and at work which is 14 miles away. I don't like the fact that the power cable doesn't have a locking device.

    If it gets ripped off, we will need a replacement.

    The Dealer price will be Inflated.
    Legrand has a Level 1 Portable EV Charger - L1EVSE costing $499

    Any other suggested 120 vac Level 1 chargers?
     
  2. mitch672

    mitch672 Technology Geek

    Joined:
    Mar 10, 2004
    1,077
    197
    0
    Location:
    Randolph, MA
    Vehicle:
    Other Electric Vehicle
    Model:
    N/A
    If you are handy, you can build your own portable charger, it will be capable of L1 or L2, up to 7.2KW (30A J-1772 cabling), cost is under $500 to build one. This would charge your PiP from 240 in 1.5 hours, or from 120 in 3 hours, it will also be capable of working with your next real EV, such as a Leaf, Tesla, a Focus EV, etc. see the projects site:

    http://code.google.com/p/open-evse/
     
  3. ukr2

    ukr2 Senior Member

    Joined:
    Feb 5, 2007
    1,009
    275
    31
    Location:
    Victor, NY
    Vehicle:
    2021 Prius Prime
    Model:
    XLE
    With my concern to secure the PIP cable while charging and my desire to warm the PIP interior before driving it, inorder to keep the PIP Heater off as much as possible, here is a plan -

    When I get home, plug an extension cord in the outlet and hang the end through the backseat passenger window.
    The cord end will have a 1 x 3 splitter.
    Plug the PIP charger cable into the splitter, and with the charger cable electronics box in the interior of the car, hang the power connector out the window and plug in the PIP.
    For the 2 cables passing through the window, I'll fit a wood spacer with 2 slots for the cables and close the window up against the spacer, locking the extension cord end and the PIP cable box in the car, giving me cable security.

    To warm the car in the morning, I'll also plug a 120vac timer into the extension cord splitter in the car and plug a ceramic heater into it. Then set the timer for a half-hour before I plan to leave.

    After doing these steps a few times, it'll be fast to setup.

    Any thoughts?
     
  4. ryogajyc

    ryogajyc Active Member

    Joined:
    Aug 30, 2004
    985
    165
    0
    Location:
    Reseda, CA
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Advanced
    Page 79 of the Owner's Manual states:
     
  5. Tracksyde

    Tracksyde Member

    Joined:
    Sep 21, 2011
    1,429
    761
    0
    Location:
    So Cal
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    Even if you did, just for the EVSE you'd need something like 10 gauge extension cord, which I believe is rated for 15 amps. Adding an electric heater to the mix would likely overload the extension cord and be a fire hazard.

    It seems Chevy recommends against using an extension cord but gives guidelines if it must be done. Toyota's wording is much more straight forward against its use, it seems.
     
  6. ukr2

    ukr2 Senior Member

    Joined:
    Feb 5, 2007
    1,009
    275
    31
    Location:
    Victor, NY
    Vehicle:
    2021 Prius Prime
    Model:
    XLE
    Guys,

    A 12-gauge 3-wire 100' extension cord is rated for 15 amp without overheating. Check Home Depot.

    And the Heater would not be working while it's charging.

    I'd start charging when I get home at night and the timer would be set for the morning, 1/2 hour before I leave the house.
     
  7. mitch672

    mitch672 Technology Geek

    Joined:
    Mar 10, 2004
    1,077
    197
    0
    Location:
    Randolph, MA
    Vehicle:
    Other Electric Vehicle
    Model:
    N/A
    Charging a car is different, its a "continous load", for anything over 75', you should upsize the wire gauge, meaning for 75' or 100', you should go with a 10awg cord. There is also voltage drop on such long cords, that's the main reason to upsize the wire gauge.

    The reason Toyota recomends AGAINST using extension cords is, anything before the EVSE may not be GFCI protected, and using a 75' or 100' cord outdoors in the elements without a GFCI protecting most of it is a bad idea.
     
  8. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    108,706
    49,401
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    i am going to do the same thing, but i'm in a garage and there's no chance of having the cord stolen at work because i'm parked right outside my office. i don't see a problem with it, the statement in the manual is just cya.
     
  9. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    108,706
    49,401
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    if 14 gauge is sufficient for in home, in wall 15 amp circuit, why would an extension cord be any different. what you really need is a table to calculate your loss over the total run from circuit breaker to evse. then you'll know what size in wall cable and what size extension cord. if you run 12 ga. in wall and 12 ga. extension, you'll be fine. if you have 14 ga. in wall, not sure about extension without table, but even 14 ga. may be fine. and if the extension is plugged into gfci, you're covered.
     
  10. mitch672

    mitch672 Technology Geek

    Joined:
    Mar 10, 2004
    1,077
    197
    0
    Location:
    Randolph, MA
    Vehicle:
    Other Electric Vehicle
    Model:
    N/A
    electrician2.com Wire Size calculator

    13A continuous load calculates out to 12AWG wiring, check yourself.

    Extensions cords are different because they are not solid copper conductors (stranded), they also use different insulation than in wall wiring, there are many different factors other than the conductor sizing.

    Do whatever you want, if you burn up the built in 3.3KW charger, Toyota is not likely to cover it under warranty.
     
  11. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    108,706
    49,401
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    isn't toyota's requirement simply a dedicated 15amp circuit with gfci? do they spec 12 ga wire?
     
  12. andi1111

    andi1111 Member

    Joined:
    Jan 13, 2012
    270
    63
    0
    Location:
    EU
    Vehicle:
    2012 Chevy Volt
    Model:
    N/A
    The thickness of the wire is important due to internal losses within the wire. If the wire is to thin, than a big load will heat up the wire and also cause a drop in voltage.

    There is a formula to calculate this, but this is for European units:

    U(%)=(100 x cable length x power)/(56 x cable thickness x U x U)

    56=copper
    38=aluminium

    It goes like this. U(%) is a Voltage drop in percent. If your voltage at the beginning of the wire is 200V, then at 10% Voltage drop, the Voltage at the end of the wire will be 180V.

    Cable length is in meters.
    Power is in Watts.
    Cable thickness unit is in mm2 (as in milimeters squared).

    For example. I have a 100 meters long wire, 230V (EU) Voltage at the beginning of the wire, a 1.5mm2 thick copper cable and a 2kW power demand.

    The formula goes like this:

    U(%)=(100 x 100m x 2000W)/(56 x 1.5 x 230V x 230V)
    U(%)= 4.5%

    That means that the voltage drop will be 4.5%, which equates to final Voltage at the end of the wire at 220V. The other 10 Volts is a loss. This loss is generated as heat, so 10V * (2000W/230V = 8.7A) = 78Watts of loss.

    These 78Watts will heat up the wire. If the Power demand is higher, the voltage drop is even higher and a power loss is even bigger.

    If you want to use the above formula to calculate your needs, you can use any online conversion tool to make a conversion from feets to meters and from your Gauge wire to mm2 thickness.

    I live an apartment block and I have a 60 meters wire down to my -2nd floor of underground garage from my apartment. The cable is 5mm2 thick. I have a 25A Circuit breaker at the beginning and at the end of the wire. I also have ground fault protection at the end of the wire.
     
  13. tomkessler

    tomkessler Junior Member

    Joined:
    Jan 12, 2012
    28
    14
    0
    Location:
    Campbell, CA
    Vehicle:
    2012 Prius Plug-in
    Do you have a pointer to someone selling the legrand charger? A
    quick search didn't show me any online.
     
  14. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    108,706
    49,401
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    thank you andy, that all makes sense and sounds like the best way to do it. what i don't understand is, toyota specifies (if i'm not mistaken) a 15 amp dedicated circuit. in the u.s., most residences have 14 ga. wire supplied by 15 amp breaker. i'm sure if the distance was extremely far,using your formula, 12 ga. would be used. but as far as the 14 ga. is concerned, the breaker is supposed to trip if there is too much draw and the wire should not heat up if it doesn't.
     
  15. ukr2

    ukr2 Senior Member

    Joined:
    Feb 5, 2007
    1,009
    275
    31
    Location:
    Victor, NY
    Vehicle:
    2021 Prius Prime
    Model:
    XLE
    Legrand Site is -
    Level 1 Portable Electric Vehicle Charger, L1EVSE

    I left a message with Legrand asking where to buy it. Their main outlet, Home Depot, only shows their Level 2 charger.
     
  16. andi1111

    andi1111 Member

    Joined:
    Jan 13, 2012
    270
    63
    0
    Location:
    EU
    Vehicle:
    2012 Chevy Volt
    Model:
    N/A
    I don't know exactly, how think (in mm2) are 12 ga. and 14 ga., but 1.5mm2 thick and very long cable can have a considerable voltage drop at high loads and that's not good for the device at the end of the wire. In case of a charger, it can result in a higher current being drawn to meet the constant power demand and that could lead to charger overheating (due to higher currents) or even circuit breaker tripping.
    It can also lead to considerable warming of the wire. I've witnessed first hand, when my Vectrix and a Tazzari Zero were both charging on a single 1.5mm2 wire, 230V, 16A breaker, getting the wire very warm. My Vectrix draws 7.5A, Zero also around that number, so we were on the edge of tripping the breaker. The wire was very warm to touch. The minute, when my Vectrix reached 90% SOC and dropped power draw to 500W, the wire became cold again. And that was on a cold autumn evening.
    Danger of heating is also very different if the wire is laid in the ground or above the ground. 1.5mm2 is ok for 16A when laid in the ground, but only for 10A when above the ground.