1. Attachments are working again! Check out this thread for more details and to report any other bugs.

Transmission "Flush" with syringe

Discussion in 'Prius v Care, Maintenance and Troubleshooting' started by Anklepain, Jul 30, 2024 at 4:12 PM.

  1. Anklepain

    Anklepain New Member

    Joined:
    Jul 18, 2024
    8
    0
    0
    Location:
    Finland
    Vehicle:
    2014 Prius+ MPV
    Model:
    N/A
    What do you think about transmission "Flush" with syringe. Im thinking to suck the bottom fluid out from the draining hole with syringe. Would it be safe to do it that way? Is there something need to be conserned?
     
  2. BiomedO1

    BiomedO1 Senior Member

    Joined:
    Mar 27, 2021
    1,496
    811
    0
    Location:
    SacTown, Ca
    Vehicle:
    2021 Prius Prime
    Model:
    LE
    How are you going to properly refill it?
    What if you can't get the fill plug off?
    Do you know what a "drain plug" is? Why would you have to suck it out with a syringe?
    How big is this syringe? It would need to be able to move 4L of ATF in one go, so you can get that drain plug back onto place without losing too much ATF. :(:eek:o_O:censored::sleep:(n)

    FYI; a proper flush would involve disconnecting the ATF cooling lines from the radiator. ATF going into the radiator gets dumped into a can, the new stuff goes back to the transmission on the return line. There's no good reason to flush this transmission, it's a planetary gear style.- so most of it's wear happens during break-in.
     
    #2 BiomedO1, Jul 31, 2024 at 12:16 AM
    Last edited: Jul 31, 2024 at 10:22 AM
  3. xliderider

    xliderider Senior Member

    Joined:
    Apr 19, 2012
    7,877
    3,117
    0
    Location:
    Honolulu, HI
    Vehicle:
    2011 Prius
    Model:
    Three
    Agree with the post above. OP, you're over complicating a simple drain and fill operation.

    It's very similar to an oil change. Open fill plug, remove drain plug and let gravity do its thing. Replace drain plug, and fill the transaxle either with a funnel and tube, or you can use your syringe.

    SM-G781V ?
     
  4. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    109,053
    49,560
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    only problem is you need a lift or four jack stands
     
    xliderider likes this.
  5. John March

    John March Junior Member

    Joined:
    Aug 5, 2021
    28
    5
    0
    Location:
    Winston Salem NC
    Vehicle:
    2014 Prius v wagon
    Model:
    Three
    Technically I used a set of ramps and 2 jackstands and a lift. Definitely, not fitting under without.

    The car needs to be level so lifting just the front wont work.

    IMO - put the syringe away for some other use.

    Going off memory:

    4 Quarts ATF - WS
    small flat head for splash shield
    10mm socket for splash shield
    Fluid Pump - I found one on amazon that fits a a quart wide mouth ATF bottle that I love.
    Torx 10mm
    Extensions and ratchet

    After leveling:

    1. Remove undercover splash shield.
    2. loosen upper fill bolt (if totally removed a little fluid will start coming out)
    3. loosen lower drain bolt - have an a larger pan then you think because fluid may hit a nearby black support and the fluid empties fast.
    4. tighten up lower bolt after draining (don't recall torque specs)
    5. pump in ATF till it starts coming out the top fill hole - should be more than 3 quarts but less then 4. (3 and 3/4)
    6. tighten up top fill bolt

    Be sure you know which bolts your loosening since the inverter coolant bolt is nearby and similar looking.

    Brush up on some youtube videos - I referenced the nutz about bolts video.
     
    #5 John March, Aug 1, 2024 at 10:12 PM
    Last edited: Aug 1, 2024 at 10:17 PM
  6. xliderider

    xliderider Senior Member

    Joined:
    Apr 19, 2012
    7,877
    3,117
    0
    Location:
    Honolulu, HI
    Vehicle:
    2011 Prius
    Model:
    Three
    I believe you need a 10mm hex socket, not a torx for the drain and fill bolts.

    SM-G781V ?