Discussion in 'Gen 2 Prius Main Forum' started by qmanqman, Oct 20, 2025 at 12:58 PM.

  1. qmanqman

    qmanqman Active Member

    Joined:
    Mar 29, 2020
    395
    124
    0
    Location:
    CO
    Vehicle:
    2007 Prius
    Model:
    One
    It was in the low 50s this morning so I turned on the "Auto" function and set the temp to 70 which usually warms the interior up. Only cool air blew from the vents.

    We recently replaced the "coolant flow control valve" and had to add some coolant at the time but I never follow up checked it so I'll do that this evening. Any other thing to look at when diagnosing a problem with no heat?
     
  2. ChapmanF

    ChapmanF Senior Member

    Joined:
    Mar 30, 2008
    27,229
    17,866
    0
    Location:
    Indiana, USA
    Vehicle:
    2010 Prius
    Model:
    IV
    A coolant control valve can get stuck in a position that cuts off coolant flow through the heater core, so that can be a cause.

    The air mix door can get stuck in a position that cuts off air flow through the heater core, so that can be a cause.

    For people of typical flexibility, it isn't too hard to peek under the dash and see if the air mix door moves.
     
    qmanqman and BiomedO1 like this.
  3. qmanqman

    qmanqman Active Member

    Joined:
    Mar 29, 2020
    395
    124
    0
    Location:
    CO
    Vehicle:
    2007 Prius
    Model:
    One
    Thanks pal. This is my daughter's car and I've been driving it for the past few weeks. She just informed me that it's been doing this for years so I'm gonna guess it's probably not the flow control valve since it's been replaced twice in the last two years and once about 3 months ago. Gonna check the blend door.
     
    #3 qmanqman, Oct 20, 2025 at 1:22 PM
    Last edited: Oct 20, 2025 at 1:43 PM
  4. BiomedO1

    BiomedO1 Senior Member

    Joined:
    Mar 27, 2021
    3,272
    1,721
    0
    Location:
    SacTown, Ca
    Vehicle:
    2021 Prius Prime
    Model:
    LE
    also check the heater core lines going through the fire wall. Both should be warm, if coolant is circulating throughout the heater core. If both hoses are warm, I'd look at the blend doors.
    If one or both lines are cool to the touch; you have no coolant flow. At this point, you'll need to troubleshoot why coolant isn't flowing. Coolant bleed issue, control valve issue, clogged heater core, coolant pump issue.

    Good Luck....
     
    qmanqman likes this.