    To the electrical aficionados on the forum - should a circuit breaker supplying power to the 120v outlet trip if something like a short on the EBH wiring happens? Or would installing a GFCI outlet on that circuit be a wise move since they are more sensitive to short situations?
     
  2. DGH

    DGH Thread Terminator

    Joined:
    Aug 13, 2006
    365
    93
    0
    Location:
    Wales, WI
    Vehicle:
    Other Hybrid
    Model:
    N/A
    [​IMG][​IMG][​IMG]

    Have a million things going on today will comment on the discussion later tonight.
    New used 2008 joins the others.

    Thanks,

    Dan
     
  3. 2k1Toaster

    2k1Toaster Brand New Prius Batteries

    Joined:
    Feb 14, 2010
    6,035
    3,855
    0
    Location:
    Rocky Mountains
    Vehicle:
    2006 Prius
    Model:
    Three
    If there is a short yes. But you still get 13-15A out of it generally before it trips. You are attaching a heating element to an untended metal assembly surrounded by plastic sitting in your garage. This is no different then plugging a space heater in and going to sleep. It sometimes ends badly. The short will only happen after the wires have become so hot the insulation melts off and then shorts the wires together. But by that time, you probably already have a problem.

    And something most people overlook are old circuit breakers in their main panel. If your house is a couple decades old, it is probably time to replace all the breakers. They aren't meant to be tripped over and over, and even time is an enemy. You may have a 15A breaker on the line, but it takes 20A or more for it to trip because it is too old. For a few bucks a piece, it is not worth skimping.
     
    cwerdna and DGH like this.
  4. DGH

    DGH Thread Terminator

    Joined:
    Aug 13, 2006
    365
    93
    0
    Location:
    Wales, WI
    Vehicle:
    Other Hybrid
    Model:
    N/A
    Lessen learned the hard way.
     
  5. PriusGuy32

    PriusGuy32 Prius Driver Extraordinaire

    Joined:
    Sep 10, 2012
    1,417
    510
    0
    Location:
    Harrison Township, Michigan
    Vehicle:
    2015 Prius
    Model:
    Four

    Well, my house was built in 1941 but I have a seperate panel in my garage (Really its a 3/4 garage, 1/4 boat house because I live on a canal and the back part butts up with my seawall) that has VERY old circuit breakers in them. I am going to update the outlet that I plug my engine block heater, and the outlet that goes out to my boat. I'd rather be safe than sorry.
     
  6. Agent J

    Agent J Hypoliterian

    Joined:
    Apr 27, 2010
    294
    111
    0
    Location:
    Sydney, Australia
    Vehicle:
    2007 Prius
    Model:
    N/A
    Ok, here is something interesting... I found the original plug with the suspected severed wire inside. True enough, one side sort of snapped upwards and had small burns on the ends, while the other side was unusually deformed. Could they have been that way from the factory originally?

    At first, I started slicing lengthwise after the ribbed support. Since I found nothing there, I took off the rubber support and saw a small bulge obscured by the ribbed support near the body of the plug. When I sliced it open, I saw the cut and but relieved it didn't escalate into the adjacent wires to become a full blown short. [​IMG]:eek:

    _DSC0581_DxO copy.jpg

    _DSC0588_DxO copy.jpg


    The other side
    _DSC0591_DxO copy.jpg


    _DSC0601_DxO copy.jpg


    _DSC0617_DxO copy.jpg
     

    Attached Files:

    DGH likes this.
  7. DGH

    DGH Thread Terminator

    Joined:
    Aug 13, 2006
    365
    93
    0
    Location:
    Wales, WI
    Vehicle:
    Other Hybrid
    Model:
    N/A
    Which is why I added a short heavy duty extension to eliminate stress on the hard wired cord to the EBH. The EBH plugs into the extension eliminating daily use of the EBH plug.
    What about adding an integrated 5 or 10 amp breaker to the power supply line? The EBH only draws about 3.5 amps at start up which would drop a bit after the unit heats up.
    Lastly after speaking with Toyota about my situation they are sending a forensic investigator over on Monday to see if they can determine a cause.

    Thanks,

    Dan
     
  8. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    108,918
    49,500
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    wow, impressive.(y)
     
  9. DGH

    DGH Thread Terminator

    Joined:
    Aug 13, 2006
    365
    93
    0
    Location:
    Wales, WI
    Vehicle:
    Other Hybrid
    Model:
    N/A
    Ha, I have another name for it!
     
  10. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    108,918
    49,500
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
  11. DGH

    DGH Thread Terminator

    Joined:
    Aug 13, 2006
    365
    93
    0
    Location:
    Wales, WI
    Vehicle:
    Other Hybrid
    Model:
    N/A
    Nah, just want to know what happened.
     
  12. 2k1Toaster

    2k1Toaster Brand New Prius Batteries

    Joined:
    Feb 14, 2010
    6,035
    3,855
    0
    Location:
    Rocky Mountains
    Vehicle:
    2006 Prius
    Model:
    Three
    "A full blown short" is exactly the kind of failure you want. It is the easiest to detect, and exactly what the breakers in your electrical panel are made to detect. A full blown short would have sent a couple sparks, the breaker would have tripped and the entire circuit shut off. In the morning you would have woken up to a cold car with a blown breaker. Flip the breaker back to turn it on (as most people do without thinking why it was blown in the first place) and it would immediately trip again. Not until you unplug the offending appliance would the circuit come back to life. That is what you should wish for, not a quasi-failure that causes it to have thermal runaway.
     
    DadofHedgehog and Agent J like this.
  13. DGH

    DGH Thread Terminator

    Joined:
    Aug 13, 2006
    365
    93
    0
    Location:
    Wales, WI
    Vehicle:
    Other Hybrid
    Model:
    N/A
    Well it's too bad, the block heater was a very effective tool in the winter, it worked flawlessly for seven years.
    Toyota and the insurance co. both sent investigators and determined the cause of the fire was the block heater, specifically salt deposits. How they could tell from the burnt mass I don't know.
    Throughout it's lifespan I did cover the plug and monitor the condition of the cord, but whom am I to argue.

    So I guess the lesson is keep a close eye on the whole apparatus. Of course for my two car fleet I am out of the block heater game.

    Good luck!
     
    cwerdna likes this.
  14. DadofHedgehog

    DadofHedgehog Active Member

    Joined:
    Jun 17, 2012
    681
    281
    0
    Location:
    northern Virginia
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Advanced
    ..they say that lightning never strikes twice..
     
    DGH likes this.
  15. DGH

    DGH Thread Terminator

    Joined:
    Aug 13, 2006
    365
    93
    0
    Location:
    Wales, WI
    Vehicle:
    Other Hybrid
    Model:
    N/A

    Along with once bitten twice shy....
     
    DadofHedgehog likes this.
  16. xraydoug

    xraydoug Active Member

    Joined:
    Sep 14, 2013
    571
    176
    0
    Location:
    Roseburg, Oregon
    Vehicle:
    2013 Prius c
    Model:
    Two
    I built an addition to my house and I had to use special breakers for the extra bedrooms, I think they are called ARC/SINE breakers. they are suposed to be able to detect an arc due to a faulty space heater or other elec. device and prevent fires. It seems to me that may be a great investment for anyone using block heaters. they install right into your electrical panel so it would be almost no work to do it. you just need to see what brand of elecrical panel you have and get the proper size and put it in. I am not an electrician so I am not positive this would completly protect you, but I think they are made to prevent the same type of issue that likely started this fire.

    Hope this helps(y)
     
    DadofHedgehog likes this.
  17. xraydoug

    xraydoug Active Member

    Joined:
    Sep 14, 2013
    571
    176
    0
    Location:
    Roseburg, Oregon
    Vehicle:
    2013 Prius c
    Model:
    Two
    I went to google and searched to find Arc/sine breakers. Turns out they are really Arc-Fault Circuit Interrupter breakers. I got mine from Lows I don't remember them being very expensive, so I really encourage those who use block heaters to look into these. I think if you park your car in garage or carport attached to home you would be crazy not to
    Arc-Fault Circuit Interrupter Installation in Rochester

    [Broken External Image]:http://www.doctorelectricservices.com/images/pages/electrical4.jpg
    Arc Fault Circuit Interrupters (AFCI) monitor the sine wave of certain circuits and will trip under a working fault condition. Each electric circuit in Rochester has a sine wave, that cycles on a nominal frequency of 60 cycles per second. When it arcs it causes the sine wave to act unrecognizable unlike a normal sine wave.
    When the AFCI detects an abnormal sine wave, it trips stopping what could be a working fault and potential fire hazard.
    All new construction, specifically bedrooms, must have an AFCI circuit breaker installed. Call our experts to install one for you today and start protecting your family from dangerous electrical hazards that can occur in the home
     
    DadofHedgehog likes this.