Both my cars have the same MPH averages. My Altima Hybrid which gets mostly freeway miles get about 37mph also. Pretty typical to me.
Yes I have only bottom balance my pack once. It was pretty extreme in that the static voltages after the balancing was 3.050V and it took me a...
The goal of bottom balance is to get all the cells to the same discharge point or DOD. I am not sure if the DB8 is s shunt shuffler I think it is...
In your case I would just sign up for the Nissan Leaf when it is available for preorder. Nissan claims that the price is in the range of the...
This all depends on the terrain of your drive. Also keep in mind that you need to warm up the ICE to at least 100F to get the car to stay in EV...
Just wanted to update on my bottom balanced cells. I ran my 8kWh kit to autoshut off point today underload and the switchs turned off the...
You can run the kit with low cells with safety as long as the kit is completely balanced on the discharge. If the kit was balanced the pack...
That is really strange. How can a fuse in the charger keep the converters from turning on??? The two devices are wired in parallel aren't they??...
I agree with Dan on this one. When I used the kit as a 4kWh kit, I would get to about 75% DOD or 25% SOC on a 35 mile trip. Do keep in mind that...
Just a thought. Is the 2kwH kit using Thundersky batteries? If so the overcharge point is at like some 4.25V according to the spec sheets. I...
Dan, Can you send me instructions to set my voltages for my converter? Just tested no load voltages and they are about 250V each with no load....
I notice that even when I have full bars on the OEM battery. My scanguage II is still showing a 20AMP charge going into system and eventually the...
I would actually like to hire someone to mount the box for me. I just don't have the right drill bit and lift to get under the car easily. I also...
JonnyD, I am not sure what it would be after 70 miles, it really depends on how long it takes me to get to 70 miles. I know I would not be able...
Dan, Great to see the CellLogs working. I got my first alarm today from my CellLog. I had run the batteries down to 2.80V today. My LED was so...
Well just wanted to report the results of my first full uninterrupted tank with the 8kWh Kit and 2 converters. And after replacing 16 bad cells...
Dan, I would monitoring it more closely. That is a really wide gap. With a delta of 300mV under load pretty much all the time, I would think that...
Dan, Here is a chart of the Delta between 8 of my cells for a 40 mile trip. Battery was not full and you can see my max Delta is 180mv and that...
Dan, Looking at you graph. You have a Delta of about 300mv between your cells. That is pretty wide gap. Your discharge is really unbalanced and...
Daox, It uses the same connector as the DB8. It is plug and play. You can get some from ebay. I had extras since I was given 8 balancers for my...